January 2012 4.10 List of Machine Parameters 437
PLC
Settings for PLC run-time system
CfgPlcPeriphery
Configuration of PLC peripheral devices:
IOC configuration, assignment of logical to physical PLs; behavior of the override potentiometers;
Reaction of the PT100 inputs, etc.
iocProject
103402
Configuration file for IOC hardware
Specifies the path/file name of the configuration
file for HSCI and PROFIBUS components.
Format: String
Input: Path/name of the IOC file
Max. 260 characters
RESET
LEVEL3
597 110-03
1516
iocOption
103403
Option data for IOC hardware (HSCI,
PROFIBUS)
By inserting "–" in front of the name of the option,
it can be disabled.
Format: List [0 to 100]
Input: String, max. 32 characters
RESET
LEVEL3
1517
pt100Discrete
103404
MP4020.7
Transfer of PT100 values
Format: Selection menu
Input:
TRUE:
Transfer value immediately
FALSE:
Transfer value at 1 K/s
Default: TRUE
PLC/Pgm
run is
locked
LEVEL3
1369
tempCompensation
103405
MP4070
Compensation of thermal expansion
Compensation speed for lag-tracking axis-error
compensation
Format: Numerical value
Input: 0 to 359 999.64 [mm/min]
PLC/Pgm
run is
locked
LEVEL3
721
overrideFullRatio
103406
(optional parameter)
Compensation for cable losses of the override
potentiometers
Format: Numerical value
Input: 0.5 to 1.0
Default: 0.98
PLC/Pgm
run is
locked
LEVEL3
1360
Parameter
MP number
iTNC MP number
Function and input Behavior
Access
SW vers.
Page

Table of Contents