454 HEIDENHAIN Technical Manual MANUALplus 620
singular
104114
(optional parameter)
Function is output in a separate strobe
With the "singular" parameter you can prevent the
function from being output in a strobe together
with other functions. If several M, S, T functions
are programmed in an NC block, the strobes can
be set in parallel by the NC. With this parameter,
you can exclude the current function from this
parallel collection and simultaneous transmission
in one strobe.
Format: Selection menu
Input:
TRUE:
Function is output in a separate strobe.
Combined output is prevented.
FALSE:
Function can be combined with other functions
RESET
LEVEL3
1580
blockSearch
104115
Code output also during block scan
Format: Selection menu
Input: TRUE or FALSE
TRUE:
Function is also output during the block scan
FALSE:
Function is not output during the block scan.
The function is collected and restored.
Default: FALSE
RESET
LEVEL3
1581
Parameter
MP number
iTNC MP number
Function and input Behavior
Access
SW vers.
Page