January 2012 4.10 List of Machine Parameters 473
hideWriteProtected
106504
Hide write-protected parameters
Format: Selection menu
Input:
TRUE:
Hide write-protected configuration objects.
FALSE:
Display all configuration objects
Default: TRUE
PLC/Pgm
run is
locked
LEVEL3
350
Network
Configuration of interface connections
Serial
Configuration of serial interfaces
CfgSerialPorts
Data record belonging to the serial port;
The data record for configuring the serial port is stored in MP_CfgSerialInterface.
activeRs232
106601
(optional parameter)
Enable the RS-232 interface in the program
manager
Format: Selection menu
Input:
TRUE:
The RS-232 interface is enabled in the program
manager and shown as a drive icon (RS232:).
FALSE:
The RS-232 interface cannot be accessed via
the program manager.
Default: FALSE
NOTHING
LEVEL2
597 110-03
1773
interfaceRs232
106602
Key name of the data record for the RS-232
interface
Define the default parameter set for the serial
RS-232 interface here. The "Default" data record is
selected by default. But you can use any desired
designation. The specified data record must be
contained in CfgSerialInterface. The data record
is not effective if another record was activated by
the PLC.
Format: String
Input: Max. 18 characters
NOTHING
LEVEL2
1773
Parameter
MP number
iTNC MP number
Function and input Behavior
Access
SW vers.
Page