474 HEIDENHAIN Technical Manual MANUALplus 620
interfacePlc
106605
Key names of the data records for interface
access by the PLC
Here you can enter a maximum of three different
key names for interface accesses by the PLC. If
no parameter set is specified, the control
automatically uses the default parameter set
defined in CfgSerialInterface.
Format: List [0 to 2]
Input: String, max. 18 characters
NOTHING
LEVEL2
1773
baudRateLsv2
106606
Data transfer rate for LSV2 communication in
baud
Format: Selection menu
Input: BAUD_110
BAUD_150
BAUD_300
BAUD_600
BAUD_1200
BAUD_2400
BAUD_4800
BAUD_9600
BAUD_19200
BAUD_38400
BAUD_57600
BAUD_115200
Default: BAUD_115200
NOTHING
LEVEL2
1774
CfgSerialInterface
Definition of data records for the serial ports;
[Key name of the data record for the serial port]
Under each key name, the properties of a serial port are defined. The data record to be active is
specified under CfgSerialPorts.
baudRate
106701
MP5040
Data transfer rate in baud
Format: Selection menu
Input: BAUD_110
BAUD_150
BAUD_300
BAUD_600
BAUD_1200
BAUD_2400
BAUD_4800
BAUD_9600
BAUD_19200
BAUD_38400
BAUD_57600
BAUD_115200
Default: BAUD_9600
NOTHING
LEVEL2
1775
Parameter
MP number
iTNC MP number
Function and input Behavior
Access
SW vers.
Page