January 2012 4.10 List of Machine Parameters 477
bccAvoidCtrlChar
106708
MP5020 bit 1
(optional parameter)
Block Check Character (BCC) is not a control
character
Format: Selection menu
Input:
TRUE:
Ensures that the check sum does not
correspond to a control character
FALSE:
Function not active
Default: FALSE
NOTHING
LEVEL2
1781
rtsLow
106709
MP5020 bit 8
Idle state of the RTS line
Format: Selection menu
Input:
TRUE:
The idle state of the RTS line is logical LOW
FALSE:
The idle state of the RTS line is at logical HIGH.
Default: FALSE
NOTHING
LEVEL2
597 110-03
1782
noEotAfterEtx
106710
MP5020 bit 9
Defines the behavior after reception of an ETX
control character
Format: Selection menu
Input:
TRUE:
No EOT control character is sent after reception
of an ETX control character.
FALSE:
The control sends an EOT control character
after reception of an ETX control character.
Default: FALSE
NOTHING
LEVEL2
1782