478 HEIDENHAIN Technical Manual MANUALplus 620
CfgServiceRequest
Settings for the TeleService 2.0 software for PCs;
Configuration of the SERVICE-REQUEST soft keys. Can be used by the machine operator to initiate a
service request if servicing is required.
name
114601
(optional parameter)
Logical name of the service host
The name identifies the remote service host and
can be displayed on the user interface of the
control.
Format: String
Input: Max. 500 characters
NOTHING
LEVEL2
597 110-03
1790
host
114602
(optional parameter)
Network address or host name of the remote
service host
Enter the network address as four decimal
numbers separated by periods (IP address in
dotted-decimal notation) or as a fully qualified host
name (e.g.
192.168.10.51
\HOME\DATA\SERVICE
Format: String
Input: Max. 500 characters
NOTHING
LEVEL2
597 110-03
1791
port
114603
(optional parameter)
Port number of the remote service host
The control sends the service request report to
the port entered here
Format: Numerical value
Input: 0 to 2147483647
Default: 19001
NOTHING
LEVEL2
597 110-03
1791
content
114604
(optional parameter)
Contents of the message to the remote service
host
The contents serve to identify the machine,
e.g. machine model and serial number.
Format: String
Input: Max. 500 characters
NOTHING
LEVEL2
597 110-03
1791
period
114605
(optional parameter)
Duration of repeated transmission of the
message to the service host
Transmission of the report is repeated during the
specified period of time in seconds until the
function is activated or the time entered in the
MP_timeOut parameter is exceeded.
Format: Numerical value
Input: 0 to 10 [s]
NOTHING
LEVEL2
597 110-03
1791
Parameter
MP number
iTNC MP number
Function and input Behavior
Access
SW vers.
Page