January 2012 4.10 List of Machine Parameters 479
timeout
114606
(optional parameter)
Timeout in minutes for transmission of the
message to the remote service host
Format: Numerical value
Input: 0 to 15 [min]
NOTHING
LEVEL2
597 110-03
1792
serverIp
114607
(optional parameter)
Network address or host name of the server
The data traffic of the specified server(s) is
checked. The default value is the server given in
the MP_host parameter.
Format: String
Input: Max. 500 characters
NOTHING
LEVEL2
597 110-03
1792
serverIpMask
114608
(optional parameter)
Subnet mask of the server network
Enter the subnet mask of the server as four
decimal numbers separated by periods (IP
address in dotted-decimal notation).
Format: String
Input: Max. 500 characters
NOTHING
LEVEL2
597 110-03
1792
Key code
Define code numbers
CfgChangePassword
Changing of existing HEIDENHAIN code numbers into OEM code numbers
[Key name = Existing HEIDENHAIN code number]
Specify the existing HEIDENHAIN code number to be replaced by an OEM code number, e.g. 807667,
95148, etc.
replaceWith
120501
New OEM password or code number
Specify numerals and/or capital letters.
The HEIDENHAIN password indicated in the key
name is replaced by the new OEM password
defined here.
Format: String
Input: Max. 18 characters
PLC/Pgm
run is
locked
LEVEL3
597 110-05
1232
hideOriginal
120502
(optional parameter)
Lock previous HEIDENHAIN code number
Format: Selection menu
Input:
TRUE:
The previous HEIDENHAIN code number is
disabled.
FALSE:
The previous HEIDENHAIN code number
remains in effect.
Default: FALSE
PLC/Pgm
run is
locked
LEVEL3
597 110-05
1232
Parameter