EasyManua.ls Logo

HEIDENHAIN MANUALPLUS 620 - Page 483

HEIDENHAIN MANUALPLUS 620
1818 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
January 2012 4.10 List of Machine Parameters 483
Versions
Software version of the PLC, software type and version of the NC
CfgPlcVersion
PLC program version
plcVersion
107301
PLC software version
Format: String
Input: Software version (max. 32
characters)
NOTHING
LEVEL2
versionText
Language-sensitive description for PLC version. Text name from the text resource file (for language-
sensitive texts) or texts that are understood in all languages.
dialogRes
107103
Name of a text
See entry under CfgColumnText/dialogText
NOTHING
LEVEL2
text
107103
Language-sensitive text
See entry under CfgColumnText/dialogText
NOTHING
LEVEL2
CfgNcVersion
Software version of the control;
The version is entered by HEIDENHAIN when the system is created.
[Key name for the exact software designation]
The HEIDENHAIN defaults are KERNEL and PRODUCT.
ncType
107501
Control model
Format: String
Input: Max. 16 characters,
e.g. "MANUALplus 620"
PLC/Pgm
run is
locked
LEVEL4
ncVersion
107502
NC software version
Format: String
Input: Version number of the NC software
PLC/Pgm
run is
locked
LEVEL4
CfgConfigVersion
Version of the configuration
configVersion
115501
Version code for config data
Format: String
Input: Max. 32 characters
PLC/Pgm
run is
locked
LEVEL3
versionText
115502
(optional parameter)
Description of the configuration
Format: String
Input: Max. 80 characters
PLC/Pgm
run is
locked
LEVEL3
Parameter
MP number
iTNC MP number
Function and input Behavior
Access
SW vers.
Page

Table of Contents

Other manuals for HEIDENHAIN MANUALPLUS 620

Related product manuals