484 HEIDENHAIN Technical Manual MANUALplus 620
ProbeSettings
Touch-probe configuration
CfgToolMeasuring
Specifies the behavior of the MANUALplus 620 during tool measurement.
measuringType
604601
Type of tool measurement
Enter the type of tool measurement (optical
gauge, touch probe).
Format: Selection menu
Input:
None:
No tool measurement possible
Probe:
Tool measurement with touch probe
Optic:
Tool measurement with optical gauge
PLC/Pgm
run is
locked
LEVEL1
1386
feed
604602
Measuring feed rate
Feed rate for approaching the touch probe.
Format: Numerical value
Input: –59999999940 to
+59999999940 [mm/min]
Default: 0
PLC/Pgm
run is
locked
LEVEL1
1386
distance
604603
Measuring path
The tool stops when it has traversed the
measuring range without reaching the touch
probe.
Format: Numerical value [mm]
Input: –999999999 to 999999999
Default: 0
PLC/Pgm
run is
locked
LEVEL1
1386