January 2012 4.10 List of Machine Parameters 489
Backup
Configuration of backup lists
CfgBackup
Key names of all backup lists
groupList
605501
List with the key names of all backup lists
Enter the key names of all backup lists defined
beforehand in CfgBackupGroup.
Format: List [0 to 12]
Input: Key names from
CfgBackupGroup
PLC/Pgm
run is
locked
LEVEL1
1794
CfgBackupGroup
Definition of backup lists
[Key name of the backup list]
backupFiles
605601
Paths of the configuration files
For each backup list, enter the paths of the
configuration files that are to be contained in the
respective backup list. The placeholders
%oemPath% and %usrPath% should be used
instead of the absolute paths.
Format: String
Input: Max. 500 characters
PLC/Pgm
run is
locked
LEVEL1
1794
Parameter
MP number
iTNC MP number
Function and input Behavior
Access
SW vers.
Page