522 HEIDENHAIN Technical Manual MANUALplus 620
posEncoderInput
400008
MP110, MP111
Assignment of a position encoder input to the
axis
Format: Selection menu
Input:
none:
No position encoder connected
X01...X06:
Position encoder inputs are X01 to X06 (on the
MC 42x)
X35...X38:
Position encoder inputs are X35 to X38 (on the
MC 42x)
X201...X210:
Position encoder inputs are X201 to X210 (on
the CC)
Default: none
RUN
LEVEL3
657
posEncoderSignal
400009
MP115.0, MP116.0
Signal amplitude at position encoder input
On the CC 61xx:
Encoders with 11 µA
PP
signal are not supported!
Format: Selection menu
Input:
1 Vpp:
Input signal of the encoder is 1 V
PP
11 uA:
Input signal of encoder is 11 µA
Default: 1 Vpp
RUN
LEVEL3
659
posEncoderFreq
400010
MP115.2, MP116.2
Input frequency of position encoder inputs
Format: Selection menu
Input:
fast:
Input frequency is
At 11 V
PP
: 350 kHz
At 11 µA
PP
: 150 kHz
slow:
Input frequency is 33 kHz
Default: fast
RUN
LEVEL3
659
posEncoderResistor
400011
MP115.1, MP116.1
Terminating resistor at position encoder input
Format: Selection menu
Input:
without:
Without terminating resistor
120 ohms:
With resistor
Default: 120 ohms
RUN
LEVEL3
660
Parameter
MP number
iTNC MP number
Function and input Reaction/
Access
Page