January 2012 4.10 List of Machine Parameters 545
gearShiftSpeed
401505
(optional parameter)
Speed for gear shifting
Format: Numerical value
Input: Shaft speed [rpm]
Max. 9 decimal places
RUN
LEVEL3
597 110-03
1571
gearShiftVoltage
401506
(optional parameter)
Nominal voltage value output for gear shifting
Format: Numerical value
Input: Voltage in volts [V]
Max. 9 decimal places
RUN
LEVEL3
1571
changeTurnDir
401509
(optional parameter)
Rotational direction reversal with M3 and M4
Format: Selection menu
Input:
TRUE:
Reversal of rotational direction is active with
M3/M4
FALSE:
Reversal of rotational direction is not active with
M3/M4
Default: TRUE
RUN
LEVEL3
597 110-05
664
kvFactorM19
401510
(optional parameter)
kv factor for oriented spindle stop
Only effective with active spindle orientation
(M19); replaces the value in
CfgPosControl/kvFactor.
If the parameter is not defined or 0, the value in
CfgPosControl/kvFactor is used.
Format: Numerical value
Input: 0.000 to 1000.000 [1/s]
Default: 0.000 [1/s]
RUN
LEVEL3
1004
kvFactorTapping
401511
(optional parameter)
kv factor for tapping
Only effective during thread cutting; replaces the
value in CfgPosControl/kvFactor.
If the parameter is not defined or 0, the value in
CfgPosControl/kvFactor is used.
Format: Numerical value
Input: 0.000 to 1000.000 [1/s]
Default: 0.000 [1/s]
RUN
LEVEL3
1039
kvFactorSync
401512
(optional parameter)
kv factor for spindle synchronism
Reserved, do not assign.
RUN
LEVEL3
Parameter
MP number
iTNC MP number
Function and input Reaction/
Access
Page

Table of Contents

Other manuals for HEIDENHAIN MANUALPLUS 620