544 HEIDENHAIN Technical Manual MANUALplus 620
CfgSpindle
Machine parameters for configuring the spindle;
Only define for an axis that is configured as spindle.
fastInputType
401501
Treatment of the fast input for the spindle
Format: Selection menu
Input:
none:
Spindle does not have any trip dog for reference
end position (no signal) or the signal is not
evaluated.
forStopping:
For M19 without rotary encoder, the spindle is
stopped at the trip dog upon receiving this input
signal.
forReferencing:
The input signal is used as spindle reference
signal. The MANUALplus 620 handles the signal
of the trip dog for reference end position as
reference pulse of the encoder.
Default: none
RUN
LEVEL3
1006
fastInput
401502
(optional parameter)
Number of the fast PLC input for the spindle
reference run
Format: Numerical value
Input: 0 to 32767
RUN
LEVEL3
1006
zeroPosEdge
401503
(optional parameter)
Evaluation of the edge
Cam edge indicating the position of 0° for positive
direction of spindle rotation.
Eingabe:l
zeroOne:
Zero-one transition
oneZero:
One-zero transition
RUN
LEVEL3
1007
stopOnSwitchSpeed
401504
(optional parameter)
Shaft speed for positioning to the trip dog
If the value forStopping is entered in
MP_fastInputType, the shaft speed for
positioning to the trip dog must be entered here.
Format: Numerical value
Input: Shaft speed [rpm]
Max. 9 decimal places
Default: 0
RUN
LEVEL3
1007
Parameter
MP number
iTNC MP number
Function and input Reaction/
Access
Page