562 HEIDENHAIN Technical Manual MANUALplus 620
ampAcFailSelection
401207
Signal for powerfail
Defines whether the powerfail in the control is
generated via the AC-fail and/or the powerfail
signal of the power module.
Format: Selection menu
Input:
AC fail only generated:
Only AC-fail signal
Power fail and AC fail generated:
Powerfail and AC-fail signals
AC fail / power fail inactive:
AC fail and powerfail deactivated
Power fail only generated:
Only powerfail signal
Default: Power fail only generated
RUN
LEVEL3
934
ampFactorI2t
401208
MP2304.x
(optional parameter)
Reference value for I
2
t monitoring of the
power module
Format: Numerical value
Input: 0.000 000 000 to 1000
[· rated current of power module]
0: Monitoring is switched off
1: Rated current of power module
is
reference value
Default: 1
RUN
LEVEL3
970
Parameter
MP number
iTNC MP number
Function and input Reaction/
Access
Page