584 HEIDENHAIN Technical Manual MANUALplus 620
CfgGlobalProperties
General settings for automatic operation
lifeTime
601801
Tool life management
Enable/disable the tool management according to
either the tool life or the workpiece quantity
Format: Selection menu
Input:
on:
Monitoring on
off:
Monitoring off
Default: Off
RUN
LEVEL1
1408
iStopT
601802
Tool change with interpreter stop
Configure whether an interpreter stop is to take
place before the tool change.
Format: Selection menu
Input:
TRUE:
Interpreter stop before tool change
FALSE:
No interpreter stop
Default: FALSE
RUN
LEVEL1
1415
threadDwell
601803
Dwell time for tapping
Specify for how many seconds the NC program is
to be halted during tapping when the end of the
thread has been reached.
Format: Numerical value
Input: 0 to 65535
Value as a whole number in [s]
Default: 0
RUN
LEVEL1
1415
Parameter
MP number
iTNC MP number