596 HEIDENHAIN Technical Manual MANUALplus 620
DefaultG14
602009
Tool change position "GWW" for new units
Specify the default setting for the axis order in the
START unit (GWW parameter) that is used to
approach the tool change position.
Format: Selection menu
Input: No axis
0: Simultaneous
1: First X, then Z
2: First Z, then X
3: Only X
4: Only Z
Default: 0: Simultaneous
RUN
LEVEL1
1419
DefaultCLT
602010
Coolant for new units
Specify the default setting for the coolant in the
START unit (CLT parameter).
Format: Selection menu
Input: 0: Without
1: Circuit 1 on
2: Circuit 2 on
Default: 1: Circuit 1 on
RUN
LEVEL1
1419
DefaultG60
602011
Protection zone "G60" for new units
Specify the default setting for the protection zone
in the START unit (parameter G60).
Format: Selection menu
Input: 0: Active
1: Inactive
Default: 0: Active
RUN
LEVEL1
1419
DefGlobG47P
602012
Global safety clearance G47
Specify here the default setting for the global safety
clearance in the START unit (parameter G47).
Format: Numerical value
Input: –999999999 to 999999999 [mm]
Max. 9 decimal places
Default: 2 [mm]
RUN
LEVEL1
1419