There are also two possibilities for starting the brake test. In both cases the
function described above is used to test the brakes of synchronized axes
sequentially:
Automatic brake test:
The brake test takes place automatically during the power-up test of the
control, as soon as all servo drives of the respective synchronized axis have
been switched on. Depending on the setting in MP_autoBrakeTest, the
brakes of the slave drives are tested either sequentially or together with the
master.
Brake test via PLC module:
The brake test can be activated axis-specifically by the PLC program with
PLC module 9143. Depending on the setting in MP_autoBrakeTest, the
brakes of the slave drives are tested either sequentially or together with the
master. As a prerequisite for the brake test of a synchronized axis, all servo
drives of the axis must be switched on and the brakes must be open.
MP_autoBrakeTest
Motor brake test for synchronized axes.
Available from NCK software version: 597 110-05.
Format: Selection menu
Selection: off
The brake is tested separately for this axis.
with Master
The brake for this axis is tested at the same time as the master
axis.
Default: off
Access: LEVEL3