824 HEIDENHAIN Technical Manual MANUALplus 620
Note
For filters of the "position" type, the cutoff frequencies of the axes should
not differ significantly.
Values between 20 Hz and 40 Hz are recommended for the cutoff
frequencies of the second nominal position value filter.