896 HEIDENHAIN Technical Manual MANUALplus 620
Machine
parameters
MP_motEncCheckOff
Monitoring functions
Available from NCK software version: 597 110-01.
Format: Numerical value
Input: Bit 2 – Power limit of spindle with ERR.IZ.GR
(only for
HEIDENHAIN inverters, except UE 2xx)
0: Power limit active
1: Power limit inactive
Default: 0
Access: LEVEL3
Reaction: RESET
MP_motPMax
Power limiting of motor
Available from NCK software version: 597 110-01.
Format: Numerical value
Input: 0.000 000 000 to 3200 [kW]
0: No power limiting
Default: 0
Access: LEVEL3
Reaction: RESET
MP_motMMax
Maximum torque
Available from NCK software version: 597 110-01.
Format: Numerical value
Input: 0 to 30 000 [Nm]
0: No torque limiting
Default: 0
Access: LEVEL3
Reaction: RESET