Keysight M8000 Series of BER Test Solutions User Guide 535
Working with Measurements 8
Parameters Window: For details, refer to Parameter Sweep Plugin
Parameters on page 535.
Measurement Graph: For details, refer to Measurement Graph for
Parameter Sweep on page 537.
Measurement Data: For details, refer to Measurement Data for
Parameter Sweep on page 539.
Parameter Sweep Plugin Parameters
Measurement Setup
The measurement setup includes the following acquisition parameters:
Analyzer - This parameter lists all available Data In locations that are
used for data acquisition.
Sweep Location - This parameter sets the location/location group
string against which the sweep property needs to be performed.
Sweep Parameter – This parameter sets the sweep parameter to be
swept amongst the list of other parameters present in current location
or group.
Sweep Mode - This parameter sets the sweep mode. The choices are
‘ABSolute’ and ‘RELative’.
In the ‘ABSolute’ mode, the property will sweep from the value
specified in the ‘Sweep From’ parameter to a value specified in the
‘Sweep To’ parameter.
In the ‘RELative’ mode, the property will be sweep from a value
relative to the current value specified in the ‘Sweep From’ parameter
to a value relative to the current value specified in the ‘Sweep To’
parameter.
Sweep Relax Time - This parameter sets the relaxing time between the
sweep before reading the BER. The relaxing time can be between 0 sec
to 60 sec.
Sweep From - This parameter sets the value from where the sweep
needs to be performed for that particular parameter.
Sweep To - This parameter sets the value till the sweep needs to be
performed for that particular parameter.
Steps - This parameter sets the value as for how many steps user
wants to sweep the parameter between the current “Sweep From” and
“Sweep To” range.
Steps Accumulation End - This parameter sets the steps accumulation
end criteria to sweep. The choices are “No. of Bits” or “Pass/Fail”.

Table of Contents

Other manuals for Keysight Technologies M8000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies M8000 Series and is the answer not in the manual?

Keysight Technologies M8000 Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelM8000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals