Keysight M8000 Series of BER Test Solutions User Guide 393
Setting up Patterns 7
Application Specific Patterns
This section describes how to select the patterns for a specific standards.
These patterns are applicable for M8045A and AWG (M8195A/M8196A)
modules.
OIF CEI
OIF CEI QPRBS13-CEI
This pattern is defined in CEI 56G-VSR-PAM4 appendix 16.C.3.1.
1 Select PRBS13-1 from hardware PRBS generator or use the factory
pattern available at the following location:
Factory\CEI\PRBS13Q-CEI_bit
2 Choose Line Coding as PAM4.
3 Set Symbol Mapping to Gray Coded (Default).
OIF CEI QPRBS31-CEI
This pattern is defined in CEI 56G-VSR-PAM4 appendix 16.C.3.2.
1 Select PRBS31-1 from hardware PRBS generator.
2 Choose Line Coding as PAM4.
3 Set Symbol Mapping to Gray Coded (Default).
IEEE 802.3
IEEE 802.3 QPRBS13
This pattern is defined in IEEE 802.3 clause 94.2.9.3. It is stored in a way
that will output the correct PAM4 symbols when Symbol Mapping is set to
Gray Coded.
1 Select the factory pattern available at the following location:
Factory\IEEE\QPRBS13_Lane0_bit_SelectGrayCoded
2 Choose Line Coding as PAM4.
3 Set Symbol Mapping to Gray Coded (Default).

Table of Contents

Other manuals for Keysight Technologies M8000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies M8000 Series and is the answer not in the manual?

Keysight Technologies M8000 Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelM8000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals