EasyManua.ls Logo

Omron FQ2-S/CH Series

Omron FQ2-S/CH Series
590 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Adjusting the Images That Were Taken
FQ2-S/CH User’s Manual
121
3
Taking Images
• Measurement Data That Can Be Logged
The values below can be logged as measurement data.
Parameter Setting Description
Judgement
-2: No judgement (not measured)
0: Judgement is OK
-1: Judgement is NG
-15: Out of range error
This is the judgement result.
Scroll X -99,999.9999 to 99,999.9999 This is the amount of position compensation for the X
coordinate.
Scroll Y -99,999.9999 to 99,999.9999 This is the amount of position compensation for the Y
coordinate.
Midpoint X -99,999.9999 to 99,999.999 This is the X coordinate of the measured edge midpoint
position.
Midpoint Y -99,999.9999 to 99,999.999 This is the Y coordinate of the measured edge midpoint
position.
Edge 0 position X -99,999.9999 to 99,999.9999 This is the X coordinate of the measured edge 0 position.
Edge 0 position Y -99,999.9999 to 99,999.9999 This is the Y coordinate of the measured edge 0 position.
Edge 1 position X -99,999.9999 to 99,999.9999 This is the X coordinate of the measured edge 1 position.
Edge 1 position Y -99,999.9999 to 99,999.9999 This is the Y coordinate of the measured edge 1 position.

Table of Contents

Related product manuals