Reading with OCR
FQ2-S/CH User’s Manual
161
4
Setting Up Inspections
3 Touch [Common Setting], and then set Auto Update, Back margin and Ahead margin.
Touching [Date update], date and time of Verify String will be updated.
4 Touch [Back].
Item Setting Description
Auto Update
• Not update
• First Update
• Always update (Default)
Select the condition for updating the date. The time is always
updated.
Not update
The date is not automatically updated. Update the date using the menu.
First Update
Updates the Sensor day and time information at the first launch.
Always update
The date is updated when measurement is performed. When the
controller is kept running more than one day, the date is updated
the first time measurement is performed after the date changes.
Ahead margin
Range: 0 to 99
Default: 0
Set an appropriate count back time from the current time. Set in
units of minutes.
Set this when the printing time is different from the inspection time.
Back margin
Range: 0 to 99
Default: 0
Set an appropriate count forward time from the current time. Set in
units of minutes.
Set this when the printing time is different from the inspection time.