Reading Barcodes
182
FQ2-S/CH User’s Manual
Step 3 Setting Verification Conditions
You can register a character string from a barcode to use it to verify that the character string that was read from
a barcode matches the registered character string.
You can register up to 32 character strings for verification in the master data.
You can verify the character string in the inspection against up to 32 character strings that are registered in the
master data.
The verification result is saved in an external reference parameter, so you can use a communications
command to output it to an external device.
External Reference Parameters: p. 477
[Inspect] [Inspection] [Add item.] [Bar code] [Settings] Tab Page
You can use the menu commands that are displayed for at the right of the display to adjust the settings that
resulted from teaching.
[Insp. region]: You can change the measurement region.
[Camera setup]: You can adjust the Camera focus, brightness, and other factors to input a better image.
Adjusting Image Quality: p. 76
[Meas. Parameter]: You can change the type of code to read, the read settings, etc.
Detailed Parameters: p. 186
[Continuous test]: You can start test measurements of displayed images for the settings that were taught.
Performing Test Measurements: p. 340
1 Press [Verification].
2 Press [Master data regist.].
3 Press the character string to register in the master data.