Inspecting with Color Data Inspection Item
FQ2-S/CH User’s Manual
295
4
Setting Up Inspections
Step 2 Teaching
Teaching means to store the region and the average color in the region as reference data for the measurement.
[Inspect] [Inspection] [Add item.] [Color Data] [Settings] Tab Page
The following data is stored as the measurement reference.
1 Press [Teach].
2 Place the object that is to be used as the measurement reference in front of the camera.
3 Move the rectangle to the location to be measured.
4 Press [OK].
5 Press [TEACH] on the lower right of the display.
The basic settings will be registered when teaching has been completed.
6 Press [Back] to end teaching.
Changing the measurement region: p. 227
Item Parameter Description
Reference data
Reference color R The R average to use as a reference is set automatically.
Reference color G The G average to use as a reference is set automatically.
Reference color B The B average to use as a reference is set automatically.
Drag a corner to size the rectangle.
Drag the rectangle to move it.