Menu Tables
FQ2-S/CH User’s Manual
449
Appendices
9
Inspection
Settings
Judgement
2D-code
Num. of char.
Displays the number of characters that
were read.
--- ---
p. 193
Characters
Displays the character string that was
read.
--- ---
Overall quality
Displays the evaluation value of over-
all quality.
0 to 4 ---
Decode
Displays the evaluation value of
decode.
--- ---
Cell Contrast
Displays the evaluation value of cell
contrast.
--- ---
Cell Modulation
Displays the evaluation value of cell
modulation.
--- ---
Fixed pattern
damage
Displays the evaluation value of fixed
pattern damage.
--- ---
Axial nonunifor-
mity
Displays the evaluation value of axial
nonuniformity.
--- ---
Grid nonunifor-
mity
Displays the evaluation value of grid
nonuniformity.
--- ---
Unused err.
Corr.
Displays the evaluation value of
unused error correction.
--- ---
Print scale
Displays the evaluation value of the
print scale.
--- ---
Print scale X
Displays the evaluation value of print
scale X.
--- ---
Print scale Y
Displays the evaluation value of print
scale Y.
--- ---
2D-code(DPM)*
3
Contrast
Sets the upper and lower limits of the
contrast that is to be judged as OK.
0 to 100
(Defaults: lower limit: 0
upper limit: 100)
Scene
p. 205
Focus
Sets the upper and lower limits of the
focus that is to be judged as OK.
0 to 100
(Defaults: lower limit: 0
upper limit: 100)
Scene
Cell Recog. Rate
Sets the upper and lower limits of the
cell recognition rate that is to be
judged as OK.
0 to 100
(Defaults: lower limit: 0
upper limit: 100)
Scene
Num. of char. Displays the number of characters that
were read.
---
---
Characters Displays the character string that was
read.
---
---
Cell size Outputs the number of pixels per cell
of the scanned code.
---
---
Overall quality
Displays the evaluation value of over-
all quality.
0 to 4 ---
Decode
Displays the evaluation value of
decode.
--- ---
Cell Contrast
Displays the evaluation value of cell
contrast.
--- ---
Cell Modulation
Displays the evaluation value of cell
modulation.
--- ---
Fixed pattern
damage
Displays the evaluation value of fixed
pattern damage.
--- ---
Axial nonunifor-
mity
Displays the evaluation value of axial
nonuniformity.
--- ---
Grid nonunifor-
mity
Displays the evaluation value of grid
nonuniformity.
--- ---
Unused err.
Corr.
Displays the evaluation value of
unused error correction.
--- ---
Menu command Description Setting range Data