RL78/F13, F14 CHAPTER 16 SERIAL INTERFACE IICA
R01UH0368EJ0210 Rev.2.10 1081
Dec 10, 2015
(b) When arbitration loss occurs during transmission of extension code
1: IICS0 = 0110×010B
Sets LREL0 = 1 by software
2: IICS0 = 00000001B
Remark : Always generated
: Generated only when SPIE0 = 1
×: Don’t care
(c) When arbitration loss occurs during transmission of data
(i) When WTIM0 = 0
1: IICS0 = 10001110B
2: IICS0 = 01000000B
3: IICS0 = 00000001B
Remark : Always generated
: Generated only when SPIE0 = 1
ST AD6 to AD0 R/W ACK D7 to D0 D7 to D0ACK ACK SP
2
1
ST AD6 to AD0 R/W ACK D7 to D0 D7 to D0ACK ACK SP
3 2
1