17.15.1.3 Frequency response analysis calibration settings
FRANalysis:CALibration:CALibration................................................................................668
FRANalysis:CALibration:RESult?.....................................................................................668
FRANalysis:CALibration:STATe....................................................................................... 668
FRANalysis:CALibration:CALibration
Runs a calibration sequence.
Usage: Event
Manual operation: See "Start calibration" on page 269
FRANalysis:CALibration:RESult?
Returns the result of the calibration.
Return values:
<States> PASS | FAIL | RUN | NOAL
PASS: the calibration is successful.
FAIL: the calibration failed.
RUN: a calibration cycle is running.
NOAL: no active calibration.
*RST: NOAL
Usage: Query only
Manual operation: See "Start calibration" on page 269
FRANalysis:CALibration:STATe <UseCalibrationDat>
Sets the state of calibration.
Parameters:
<UseCalibrationDat> ON | OFF
*RST: OFF
Manual operation: See "Use calibration data" on page 269
17.15.1.4 Frequency response analysis diagram settings
FRANalysis:PHASe:ENABle............................................................................................669
FRANalysis:PHASe:OFFSet............................................................................................669
FRANalysis:PHASe:SCALe.............................................................................................669
FRANalysis:GAIN:ENABle.............................................................................................. 669
FRANalysis:GAIN:OFFSet.............................................................................................. 669
FRANalysis:GAIN:SCALe............................................................................................... 670
FRANalysis:AMPLitude:SCALe....................................................................................... 670
FRANalysis:AMPLitude:ENABle...................................................................................... 670
FRANalysis:AMPLitude:OFFSet...................................................................................... 670