EasyManua.ls Logo

Scanlab RTC6 PCIe Board - Using Several Correction Tables

Scanlab RTC6 PCIe Board
1004 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RTC6 boards
Doc. Rev. 1.0.21 en-US
8 Advanced Functions for Scan Head Control and Laser Control
241
innovators for industry
8.5.3 Using Several
Correction Tables
The RTC6 PCIe Board memory can store 8 different
correction tables at the same time.
It can be useful to work with several different
correction tables even if only a single scan system (2D
or 3D) is used. Example: a pilot laser and a working
laser with different wavelengths are used.
Special applications sometimes also require different
correction tables in quick succession. This change can
be done, for example, by
select_cor_table( n, 0 )
or
select_cor_table_list( n, 0 )
(
n
= 1…
number_of_correction_tables
).
number_of_correction_tables serves to protect
other commands (for example, load_correction_file
and select_cor_table) from unwanted table
numbers.
There is no need to change existing user programs
except when user input is to be rejected in the future
(by means of explicit RTC6 error messages).