RTC6 boards
Doc. Rev. 1.0.21 en-US
10 RTC6 Commands
572
Ctrl Command periodic_toggle
Function Like periodic_toggle_list, but a control command.
Call
periodic_toggle( Port, Mask, P1, P2, Count, Start )
Parameters
Port
Like periodic_toggle_list.
Mask
Like periodic_toggle_list.
P1
Like periodic_toggle_list.
P2
Like periodic_toggle_list.
Count
Like periodic_toggle_list.
Start
Like periodic_toggle_list.
Comments • See periodic_toggle_list.
• If an unallowed parameter value is supplied for
Port
or 0 for
P1
or
P2
, then
periodic_toggle is not executed (get_last_error return code
RTC6_PARAM_ERROR
).
• See also Chapter 9.4 ”Periodical I/O Signals”, page 301.
RTC4RTC6 New command.
RTC5RTC6 Unchanged functionality.
Version info Available as of DLL 600, OUT 600, RBF 600.
Last change DLL 605, OUT 605: endless toggling with
Count
= 2
32
–1.
References periodic_toggle_list