8 Advanced Functions for Scan Head Control and Laser Control
239
innovators for industry
By set_offset_xyz or set_offset_xyz_list, an
offset can be defined for the z coordinate. In
addition, set_defocus or set_defocus_list can be
used for defining an offset to the calculated focal
length, which then appropriately affect the z
output value (in the direction opposite to the
offset).
During a marking process, the scan system focal
length is continuously readjusted. During
execution of a Jump Command (or goto_xyz) this
readjustment can be switched off. With
DirectMove3D
= 1 in set_delay_mode or
set_delay_mode_list, the z output value is
directly (linearly) taken to its final value during
the jump.
Adjusting Tracking Errors
If the xy scan head and the Dynamic Focusing Unit
unit of a 3D scan system have different
Tracking Errors, set_timelag_compensation can be
used to delay the output of the faster component to
that of the slower component.
The laser control signal output is synchronized with
the slower component. This allows, for example,
Sky Writing with 3D commands without permanent
defocusing.
In case of a SCANahead System, the
PreviewTime
parameter from set_scanahead_params is
automatically used as “Tracking Error“.