10 RTC6 Commands
537
innovators for industry
Normal List
Command
mark_serial_abs
Function Marks the current serial number of the serial-number-set most recently selected by
select_serial_set_list (or of serial-number-set 0 after load_program_file) in the selected
format at the current position. In the called indexed text strings or characters (see below),
any absolute Vector Commands and “Arc” Commands receive an offset (based on the
current coordinates at the time of the call). Afterward the serial number is (optionally)
automatically incremented.
Call
mark_serial_abs( Mode, Digits )
Parameters
Mode
See mark_serial.
Digits
See mark_serial.
Comments mark_serial_abs has the same effect as mark_serial; however, internal calling of the
indexed text strings (or characters) is by list_call_abs instead of list_call.
If the command lists of the called indexed text strings (or characters) contain no
absolute commands, then there is no difference between mark_serial_abs and
mark_serial.
RTC4RTC6 New command.
RTC5RTC6 Unchanged functionality.
Version info Available as of DLL 600, OUT 600, RBF 600.
References mark_serial