10 RTC6 Commands
741
Normal List
Command
set_sky_writing_para_list
Function Like set_sky_writing_para, but a list command.
Call
set_sky_writing_para_list( Timelag, LaserOnShift, Nprev, Npost )
Parameters
Timelag
Like set_sky_writing_para.
LaserOnShift
Like set_sky_writing_para.
Nprev
Like set_sky_writing_para.
Npost
Like set_sky_writing_para.
Comments • set_sky_writing_para_list can be executed within a list, even if Sky Writing Mode 2 or
Sky Writing Mode 3 is active. Here, an already-begun Mark Command is finished with
Sky Writing Mode 1 and the next is started with it.
• By set_sky_writing_para_list, you cannot switch from Sky Writing Mode 2 or
Sky Writing Mode 3 to Sky Writing Mode 1 permanently. For this, use
set_sky_writing_mode_list.
• Deactivation of Sky Writing Mode 1, Sky Writing Mode 2 or Sky Writing Mode 3 by
set_sky_writing_para_list results in the addition of a Mark Delay defined prior to
activation of Sky Writing – provided that no other delay is in effect (for example, a
Jump Delay).
RTC4RTC6 New command.
RTC5RTC6 Unchanged functionality.
In RTC5 Compatibility Mode, the RTC6 multiplies the value specified for
LaserOnShift
by
32. The allowed value range decreases accordingly.
Version info Available as of DLL 600, OUT 600, RBF 600.
References set_sky_writing_para