RTC6 boards
Doc. Rev. 1.0.21 en-US
10 RTC6 Commands
784
innovators for industry
Ctrl Command simulate_ext_stop
Function Causes a simulated External Stop.
Call
simulate_ext_stop()
Comments For external stops, see Section ”External Stop”, page 289.
simulate_ext_stop simultaneously halts the master board and all slave boards.
In contrast, stop_execution only halts the master board.
RTC4RTC6 New command.
RTC5RTC6 Unchanged functionality.
Version info Available as of DLL 600, OUT 600, RBF 600.
References simulate_ext_start, simulate_ext_start_ctrl, stop_execution, sync_slaves