RTC6 boards
Doc. Rev. 1.0.21 en-US
10 RTC6 Commands
561
Normal List
Command
para_mark_rel
Function Moves the laser focus at mark speed along a 2D vector from the current position to the
specified position (relative coordinate values) within a 2D Image Field. Simultaneously
varies the signal parameter selected by set_vector_control linearly to the specified value.
Call
para_mark_rel( dX, dY, P )
Parameters
dX
Relative x coordinate of the mark vector end point. In bits.
As a signed 32-bit value.
Allowed value range: [–268,435,456…+268,435,455].
Out-of-range values are clipped to the boundary values.
The complete value range is only usable as a virtual Image Field for example,
for (enabled) Processing-on-the-fly applications.
dY
Like
dX
(analogously).
P
End value of the signal parameter.
As an unsigned 32-bit value.
Allowed values: dependent on the selection made by set_vector_control
(
Ctrl
parameter), identical with set_vector_control (
Value
parameter).
Comments • The coordinates for the mark vector end point are to be supplied as relative coordinates
with respect to the current position. Otherwise, para_mark_rel is identical to
para_mark_abs (see comments there).
•
P
is not treated on a relative basis.
• [*]para_mark[*] commands generally do not take Sky Writing into account.
RTC4RTC6 New command.
In RTC4 Compatibility Mode, the RTC6 multiplies the specified values for
dX
and
dY
by 16.
The allowed value range decreases accordingly. For the parameter
P
see para_jump_abs.
RTC5RTC6 Unchanged functionality.
For the parameter
P
, see para_jump_abs.
Version info Available as of DLL 600, OUT 600, RBF 600.
References mark_rel, set_vector_control, para_mark_abs, para_mark_rel_3d