10 RTC6 Commands
400
innovators for industry
Result
(cont’d)
Bit #13 = 1: General Ethernet error. May
occur, for example, when trying
to switch by select_rtc or
acquire_rtc from
RTC6 PCIe Board to
RTC6 Ethernet Board. Further
information is provided by
n_get_error on the addressed
RTC6 Ethernet Board.
RTC6_ETH_ERROR = 8192
Bit #14 Reserved.
Bit #15 = 1: Unsupported Windows
version. May only occur during
init_rtc6_dll.
RTC6_UNSUPPORTED_WINDOWS = 32768
Bit #16 Reserved.
Bit #17 = 1: Unsupported BIOS version.
RTC6_UNSUPPORTED_BIOS = 131072
Bit #18
Bit #30
Reserved.
Reserved.
Bit #31 = 1: Can occur exclusively in
Remote Interface Mode:
Invalid Command Telegram.
See Section ”Error Codes for
get_error/get_last_error
Occurring in
Remote Interface Mode Only”,
page 919.
RTC6_REMOTE_ERROR =
2147483648
Comments For error handling see Chapter 6.8 ”Error Handling”, page 130.
get_error and n_get_error are available even without explicit access rights to a
specific RTC6 board.
The board-specific error variables
LastError
and
AccError
(see Chapter 6.8 ”Error
Handling”, page 130) are neither generated nor altered by get_error.
Bit #0 = 1 (error constant:
RTC6_NO_PCIE_CARD_FOUND = 1
) means that no
RTC6 PCIe Board has been found (init_rtc6_dll does not search for RTC6 Ethernet
Boards).
Ctrl Command get_error

Table of Contents