If the list status is queried during processing of a subroutine in the protected RTC6 List
Memory area “List 3”, then the status is returned of the list (“List 1” or “List 2”) in
which the output pointer most recently resided (typically from where the subroutine
has been originally called).
If list execution is interrupted (by pause_list, stop_list or set_wait), then the above-
mentioned status values remains unchanged.
The List Execution Status values BUSY list execution status and
PAUSED list execution status can be queried by get_status.
To read the status signals from the scan heads, use get_head_status.
RTC4RTC6 Basically unchanged functionality. However:
Additional USED list status.
RTC5RTC6 Unchanged functionality.
Version info Available as of DLL 600, OUT 600, RBF 600.
References get_status, get_head_status
Ctrl Command read_status
Ctrl Command read_user_data
Function No function.
Comments To date, read_user_data has no effect.
RTC4RTC6 New command.
RTC5RTC6 Unchanged functionality.
Version info Available as of DLL 600, OUT 600, RBF 600.