10 RTC6 Commands
437
innovators for industry
Ctrl Command get_transform
Function Like get_transform_offset, but without parameter
Channel1
,
Channel2
,
Offset
.
Call
get_transform( Number, Ptr1, Ptr2, Ptr, Code )
Parameters
Number
Number of to-be-backward-transformed position values.
As an unsigned 32-bit value.
Allowed value range: [1…2
24
].
The measured values with indices 0 to (
Number
–1) are backward transformed.
Ptr1
Like get_transform_offset.
Ptr2
Like get_transform_offset.
Ptr
Like get_transform_offset.
Code
Like get_transform_offset.
Comments
get_transform( Number, Ptr1, Ptr2, Ptr, Code )
Transfers the data pairs recorded with set_trigger/set_trigger4/set_trigger8 to the
PC with
get_waveform(1,Number, Ptr1) and
get_waveform(2,Number, Ptr2)
Overwrites the data pairwise with transform(
Sig1, Sig2, Ptr, Code
)
Comments, page 441 on get_transform_offset apply analogously.
RTC4RTC6 New command.
Even in the RTC4 Compatibility Mode, all coordinate values transferred to the PC are in the
RTC6 20-bit range. The backward transformed coordinate values must, if necessary, be
divided by 16 by users themselves.
RTC5RTC6 Basically unchanged functionality. However:
Allowed value range of
Number
remains [1…2
23
].
Version info Available as of DLL 600, OUT 600, RBF 600.
Last change DLL 635, OUT 636:
Number
. Allowed value range extended to [1…2
24
]
(previously: [1…2
23
]).
References upload_transform, transform, set_trigger, set_trigger4, set_trigger8, get_waveform,
get_transform_offset