Comments
(cont’d)
• Configuration by config_list does not alter the contents of RTC6 List Memory.
Repeating the call with differing parameters is therefore nondestructive.
However, after a configuration change, previously loaded list commands are processed
in accordance with the new configuration.
Moreover, a configuration change could in some circumstances affect the
input pointer (if, prior to the reconfiguration,
it pointed to a memory position which has been assigned to “List 3” by the
configuration change, then it is shifted to the beginning of “List 1”) or affect a
previously started automatic list change. This should be taken into account when
further loading or executing command lists.
Also observe the notes in Chapter 6.3.2 ”Configuring the RTC6 List Memory”,
page 103.
• If you do not know the current configuration data for RTC6 List Memory (
Mem1
and
Mem2
), you can find out after
load_list( ListNo, 0 )
or
set_start_list_pos( ListNo, 0 )
by using get_list_space (with “ownership” changes,
get_config_list must be called in advance).
RTC4RTC6 New command.
RTC5RTC6 Unchanged functionality. In addition: increased value range and changed initialization
values.
Version info Available as of DLL 600, OUT 600, RBF 600.
References get_config_list
Ctrl Command config_list