RTC6 boards
Doc. Rev. 1.0.21 en-US
2 Product Overview
39
Notes
• Each RTC6 PCIe Board article number indicates
which of the options above are enabled and/or
installed. These are stated in the packing list. The
naming there is as follows:
– “Fly” for Option Processing-on-the-fly
– “3D” for Option “3D”
– “SSHC” for Option “Second Scan Head
Control”
– “SCANa“ for Option “SCANa“
– “UFPM“ for Option “UFPM“
– “syncA“ for Option “syncA“
– “DCDC” for Option “DC/DC Converter”
• To query which options are actually enabled on a
board, get_rtc_version is used.
• If you need one or more options which are not
activated out of the factory on your
RTC6 PCIe Board: order an corresponding license
file from SCANLAB, specifying the serial number
and the options you want. Then, to apply the
upgrade to the board, specify it in
RTC6conf.exe
.
• For retrofitting your RTC6 PCIe Board with the
extra DC/DC converter (optoelectronic coupler)
you need to send it to SCANLAB.
• For optical data transfer between the
RTC6 PCIe Board and the scan system, solely a
suitable data cable is required, see Chapter 4.5.3
”Data Cables (Accessories)”, page 71. Neither the
RTC6 PCIe Board side nor the scan system side
requires a special optical data interface for that.
• With software package version 1.4.4, the
“Processing-on-the-fly” functionality cannot be
used for scan systems with SCANahead control.