RTC6 boards
Doc. Rev. 1.0.21 en-US
10 RTC6 Commands
492
Comments
(cont’d)
• load_auto_laser_control is not executed (get_last_error return code
RTC6_BUSY
), if:
– the BUSY list execution status is set
– the INTERNAL-BUSY list execution status is set
• load_auto_laser_control is even executed, if:
– a list has been paused by set_wait (PAUSED list execution status set)
• During the runtime of load_auto_laser_control, External Starts are suppressed.
• Before loading a table, load_auto_laser_control performs a DSP memory check that
produces error code 4 in case of error.
• The table can be saved by create_dat_file.
RTC4RTC6 New command.
RTC5RTC6 Unchanged functionality.
Version info Available as of DLL 600, OUT 600, RBF 600.
References set_auto_laser_control, create_dat_file
Ctrl Command load_auto_laser_control