RTC6 boards
Doc. Rev. 1.0.21 en-US
10 RTC6 Commands
616
innovators for industry
RTC4RTC6 New command.
In RTC4 Compatibility Mode for
Ctrl
= 1/2, the specified values for
Value
,
MinValue
and
MaxValue
are internally multiplied by 4. For
Ctrl
= 4/5, the parameter values for
Value
,
MinValue
and
MaxValue
are multiplied by 8. The allowed value ranges decrease accordingly.
RTC5RTC6 Changed functionality.
More laser control modes can be set.
Version info Available as of DLL 600, OUT 600, RBF 600.
Last change DLL 609, OUT 609, RBF 613:
Ctrl
= 7.
References load_position_control, load_auto_laser_control, set_auto_laser_params,
set_auto_laser_params_list, set_fly_x, set_fly_y, set_fly_2d, set_encoder_speed,
spot_distance, spot_distance_ctrl
Ctrl Command set_auto_laser_control