10 RTC6 Commands
730
innovators for industry
Comments
(cont’d)
For error return information, see get_scanahead_params.
Mode = 1
results in aborted set_scanahead_params execution (
Error = 3
) if no
SCANahead system is attached or it is not active. All SCANahead functionalities are
deactivated. Parameters specified for
Mode = 2
are not applied!
set_scanahead_params
( Mode = 1)
cannot be executed when an automatic laser
control is active that uses read out data from an iDRIVE scan system,
see set_auto_laser_control. You have to deactivate it temporarily.
set_scanahead_params waits until the last session has finished traversing, that is,
HEAD BUSY status (Bit #23) from get_status is no longer set.
In any case, set_scanahead_params waits no longer than 255 × [10 µs].
RTC4RTC6 New command.
RTC5RTC6 New command.
Version info Available as of version DLL 600, OUT 600.
Last change with version DLL 605: data type of
Amax
.
References get_scanahead_params, activate_scanahead_autodelays, get_last_error, get_status,
load_correction_file
Ctrl Command set_scanahead_params

Table of Contents