RTC6 boards
Doc. Rev. 1.0.21 en-US
10 RTC6 Commands
808
innovators for industry
Comments
(cont’d)
sync_slaves is not executed (get_last_error return code
RTC6_BUSY
), if:
the BUSY list execution status of the addressed board is currently set
the INTERNAL-BUSY list execution status of the addressed board is set
sync_slaves is even executed, if:
a list has been paused by set_wait (PAUSED list execution status is set)
RTC4RTC6 New command.
RTC5RTC6 Unchanged functionality. However:
Master/Slave functionality has been changed.
Version info Available as of DLL 600, OUT 600, RBF 600.
Last change DLL 615: sync_slaves has no function anymore.
References get_master_slave, get_sync_status, master_slave_config