EasyManua.ls Logo

Scanlab RTC6 PCIe Board - Page 833

Scanlab RTC6 PCIe Board
1004 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RTC6 boards
Doc. Rev. 1.0.21 en-US
10 RTC6 Commands
833
innovators for industry
Comments
(cont’d)
Because transform does not access any RTC6 board, calling it does not require explicit
access rights to a specific board. If both the upload_transform data and the queried
data recorded by get_values or get_waveform have been binarily stored on the PC,
then offline operation of transform is also possible (then transform does not require
the presence of an RTC6 board on the PCIe bus).
transform is not available as a multi-board command.
The board-specific error variables
LastError
and
AccError
(see Chapter 6.8 ”Error
Handling”, page 130) are neither generated nor altered by transform.
RTC4RTC6 New command.
In the RTC4 Compatibility Mode, all back transformed values (including z values) are in the
RTC6 20-bit range.
RTC5RTC6 Unchanged functionality.
Version info Available as of DLL 600, OUT 600, RBF 600.
References upload_transform, get_transform, get_transform_offset, get_values
Ctrl Command transform

Table of Contents