SUPPLEMENT SG-3
CHAPTER 31 - INDICATIONG SYSTEM
System software upload procedure
When the above procedure is complete, apply SW upload procedure:
Software upload procedure
Additional info
&References
Make sure that SW part number, reported on the SD
Loader Card, is the correct one.
Insert the correct G500 software Loader card into the
GDU620 top card slot
Make sure that GDU620 breaker is pulled
Optionally, the
technician may
remove power
from the stand-by
instruments by
pulling the circuit
breakers
While holding the ENT key on the GDU620, restore power
by closing the GDU circuit breaker
When the words appear in the
upper center of the PFD/MFD, release the ENT key
The system prompts the user to load the new software
version contained on the loader card in the bottom slot of
GDU620.
All G500 screen
shots used in this
document are
intended to
provide visual
reference only.
All information
depicted in screen
shots, including
software file
names, versions
and part numbers,
is subject to
change and may
not be up to date.