STARTING DESCRIPTION AND OPERATION
1. STARTER RELAY REPLACEMENT
Procedure
Step
no.
Starter switches replacement
Task description
Additional info &
References
1.
Make sure MASTER SWITCH is set to OFF
2.
Make sure that no external power is provided
3.
Remove the engine cowling
4.
Disconnect the electrical wires from the relay
5.
Remove the nut and washer fixing the relay to the
firewall.
Refer to Figure 2.
6.
Install on the panel the new relay
7.
Install the washer and nut fixing the relay
8.
Connect the electrical wires on the relay
9.
Reinstall the engine cowling
10.
Test switch for operation