EasyManua.ls Logo

Tecnam P2002 JF - Component Time Limits; Time Limits Table

Tecnam P2002 JF
1289 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2
nd
Edition - Rev 0
05-10
COMPONENT TIME LIMITS
Page 1
05-10 COMPONENT TIME LIMITS
Time limits table
This section lists the Time Between Overhauls (TBO) of components that are rec-
ommended to be replaced or overhauled within the specified time limits.
ITEM
REQUIRE-
MENT
LIMIT
ATA
Component
Part number
24
Capacitor
Kemet-ALS30A223DB025
Or BHC 105-408
Life limit
1000 hrs/4 years
WOF
25
ELT Battery Pack
452-6499
Life limit
Refer to CMM 570-
1600, latest issue
32
Brake fluid
-
Life limit
800 hrs/3 years
WOF
61
Propeller
Model HO17GHM A 174 -
177 C
Overhaul
Refer to Propeller
CMM, Last issue
72
Engine
Model 912 S2
Overhaul
Refer to Rotax En-
gine Maintenance
Manual
75
Coolant hose flexible line
92-11-105-02 Rev.B
Life limit
5 years
92-11-105-01
92-11-105-03
92-11-105-04
If applied MOD2002/53
‘Thermostatic water valve’
22-10-911-000
22-10-912-000
22-10-913-000
22-10-914-000

Table of Contents