EXTERNAL LIGHTS TROUBLESHOOTING
TROUBLESHOOTING
ATA 33-20 Troubleshooting
Trouble
Likely cause
Action required
Strobe lights do
not operate
Defective strobe light
Strobe light switch is
faulty
Wiring defective
Strobe lights breaker
is pulled out
Strobe light control
unit fails
Replace wingtip strobe light assy
Replace switch
Perform a continuity test of wiring:
repair/replace defective wiring (Red.: chap 92)
Insert strobe breaker
Replace strobe light control unit