75-10
LIQUID COOLING SYSTEM – MAINTENANCE PRACTICES
1. THERMOSTATIC VALVE REPLACEMENT
Procedure
Additional info &
References
ENSURE THAT ENGINE IS OFF AND COOL BEFORE OPERATING
MAINTENANCE ON THE THERMOSTATIC VALVE.
Set electric MASTER switch OFF
Unscrew Serflex and remove all hoses connected to
the valve
Note connections.
Refer to Figure 7.
Attach the new/overhauled unit to the support by
valve bolts
Restore the same configura-
tion noted at step 4.
Restore proper connections to the valve as noted at
step 4.
Figure 7. – Thermostatic valve Serflexes